Product catalogue
  • 3
    3

    Fire curtains separate fire compartments, slowing the spread of fire in a warehouse, production hall, shopping centre or car park for 15 to 120 minutes.

  • FK servis - Smoke barriers
    FK servis - Smoke barriers

    Smoke barriers divide a space into several smaller smoke zones. These are then easier to ventilate using a smoke and heat exhaust ventilation system.

  • Smoke and heat exhaust ventilation
    Smoke and heat exhaust ventilation

    Smoke and heat exhaust ventilation minimises property damage, makes it easier for firefighters to intervene and gives people enough time to leave the building safely.

  • Louvre windows and rooflights
    Louvre windows and rooflights

    Louvre windows certified to standard 12101-2, not just for smoke and heat exhaust ventilation systems, but also for smoke and heat exhaust ventilation of protected escape routes.

  • Electromobility
    Electromobility

    Systems and equipment for limiting the spread of electric vehicle fires, especially in public and private multi-storey car parks.

  • Daily ventilation 1
    Daily ventilation 1

    Natural ventilation systems ensure a steady flow of fresh air, removing heat and moisture. Even fully automatically.

CPS-M1-MSE

MODULAR SHEV CONTROL PANEL PACKED WITH TECHNOLOGY

A control system for smoke and heat extraction and automatic natural ventilation that can be modularly expanded to individual requirements. Ideal for controlling mechanical smoke and heat exhaust ventilation systems (MSE).

CPS-M1-MSE

Features

  • Variable modular technology for complex control requirements
  • Flexible system design thanks to a mounting rail assembly for all modules and accessories
  • Power supply and communication connection via integrated connectors
  • Possibility of retrofitting assemblies in the event of structural changes
  • Configurable MSE and ventilation functions via D+H SCS software
  • Inputs and outputs monitored for line breaks and short circuits
  • The VdS-approved AdComNet bus system for seamless interconnection of modules within the CPS-M and other D+H AdComNet components.
  • Flexible use of configurable digital inputs and outputs
  • 24 V DC: 2x max. 10 A output current on each drive module; stabilised output voltage thanks to Power Pack technology; no signal loss during a mains failure thanks to integrated emergency power supply (72 h)
  • 230 V AC: VdS-approved emergency power supply (72 h); up to 45 drives (230 V AC) can be connected per drive group (1840 VA)
  • 400 V AC: fan drive selection via inverter, soft starter or direct; power supply via the main switch, with automatic switchover to mains power if required.

Gallery

Technical data

CPS-M1-MSE
Input voltage 400 V AC
Input frequency 50 Hz
Output voltage 24 V DC / 230 V AC / 400 V AC
Ripple < 50 mVss at 24 V DC
Monitoring mode pulse operation
Protection rating IP 54
Temperature range -5 °C ... +40 °C
Material Steel
Batteries must be ordered separately.